Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Fluke 1777 Three-Phase Power Quality Analyzers
Fluke 1777 Three-Phase Power Quality Analyzers
Brand:
FLUKE
Model:
1777
Image
Image
Image
Image
Technical Data Sheets
Product Description

Fluke 1777 Three-Phase Power Quality Analyzers

Voltage Inputs:

  • Number of Inputs: 4 inputs, 3 phases and neutral referenced to PE (5 connectors)
  • Measurement Category: 1000 V CAT III / 600 V CAT IV
  • Maximum Input Voltage: 1000 V rms / 1000 V dc (1700 Vpk)
  • Nominal Voltage Range:
    • Wye and Single Phase: Variable (50 V – 1000 V)
    • Delta: Variable (100 V – 1000 V)
  • IEC 61000-4-30 Class A Compliance for Nominal Voltages (Vdin): 100 V – 690 V
  • Input Impedance: 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE
  • Bandwidth: DC to 30 kHz for PQ measurements, excluding transients
  • Resolution: 24-bit synchronous sampling
  • Sampling Frequency: 80 kS/s at 50/60 Hz
  • Scaling: 1:1, variable for use of potential transformers

Voltage Transients:

  • Measurement Range: ±8 kV
  • Sampling Rate:
    • Model 1775: 1 MS/s
    • Model 1777: 1 MS/s, 20 MS/s
  • Bandwidth: DC to 1 MHz
  • Trigger: Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz
  • Resolution: 14-bit synchronous sampling

Current Inputs:

  • Number of Inputs: 4 inputs, 3 phases and neutral, range selected automatically to attached sensor
  • Range:
    • AC:
      • 1 A to 1500 A with i17XX-FLEX1500
      • 3 A to 3000 A with i17XX-FLEX3000
      • 6 A to 6000 A with i17XX-FLEX6000
      • 40 mA to 40 A with clamp i40s-EL
      • 4 A to 400 A with clamp i400s-EL
    • DC: 20 A to 2000 A with 80i-2010-EL clamp
  • Bandwidth: DC to 30 kHz
  • Resolution: 24-bit synchronous sampling
  • Sampling Frequency: 80 kS/s at 50/60 Hz
  • Scaling: 1:1, variable
  • Input Voltage:
    • Clamp: 50 mV / 500 mV rms; CF 2.8
    • Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4
    • All at nominal probe range
  • Input Impedance: 11 kΩ

Aux Inputs:

  • Wired Connection with 17XX-AUX adapter
  • Number of Inputs: 2
  • Input Range:
    • Direct: 0 V dc to ± 10 V dc
    • 0 V to 1000 V dc
  • Input Impedance: Direct: 2.92 MΩ
  • Scale Factor: Format: mx + b (gain and offset) user configurable
  • Displayed Units: User configurable (up to 8 characters, for example °C, psi, or m/s)
Quantity:
EA
This item is sold by
Image
ID-3200346413
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power & Energy Meters from FLUKE
Source & compare similar products
More from Power & Energy Meters
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top